Skip to main content
DNA Labs India

HLA Pre-Transplant Workup Non Sensitized Recipient Panel 1 Test

DNA Labs India | ISO 9001:2015 Certified

HLA Pre-Transplant Workup Non Sensitized Recipient Panel 1 Test

Short Name: HLA Pre-Transplant Workup Panel 1

Also known as: HLA Compatibility Test for Transplant, Non-Sensitized Recipient HLA Panel

HLA Pre-Transplant Workup Non Sensitized Recipient Panel 1 Test test available at DNA Labs India for ₹22,230. Uses Complement Dependent Cytotoxicity with DTT treatment, Reverse SSOP - Luminex, Luminex X-Map technology on Whole blood and serum samples. Results in 10-12 days. Free home collection in 300+ cities across India.

Nephrology Test🏠 Home Collection

Overview

Recipient: HLA DNA Typing for Kidney/Liver transplant (PCR Low resolution Luminex), HLA T & B cell lymphocyte cross match vs potential donor, HLA Panel Reactive IgG antibodies (PRA) Screen Luminex. This workup aims to assess HLA match/mismatch, detect allo-immunization status, and identify complement-fixing allo-antibodies to predict transplant compatibility. Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_ ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_ ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_ Detect presence of complement fixing allo-antibodies in the recipient. Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_ ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_ ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_ Detect presence of complement fixing allo-antibodies in the recipient.

Test Code
816
Price
₹22,230
Sample Type
Whole blood and serum
Result Time
10-12 days
Fasting Required
No
Method
Complement Dependent Cytotoxicity with DTT treatment, Reverse SSOP - Luminex, Luminex X-Map technology

HLA Pre-Transplant Workup for Non-Sensitized Recipient Panel1 is a diagnostic test that is used to determine the compatibility of a potential donor for a non-sensitized recipient. The test is based on human leukocyte antigens (HLAs), which are proteins found on the surface of white blood cells. These antigens are inherited and vary from person to person, and if they are not compatible between the donor and the recipient, it can lead to rejection of the transplanted organ.

Symptoms and Diagnosis

HLA Pre-Transplant Workup for Non-Sensitized Recipient Panel1 is typically recommended for patients who are in need of an organ transplant. The test is used to determine the compatibility of a potential donor for a non-sensitized recipient. Non-sensitized recipients are those who have not been exposed to the HLA antigens of a potential donor through previous transplantation, blood transfusion, or pregnancy.

The symptoms of HLA incompatibility can vary depending on the type of organ being transplanted. For example, if the kidney is being transplanted, the symptoms may include fever, swelling, tenderness, and decreased urine output. If the liver is being transplanted, the symptoms may include jaundice, abdominal pain, and nausea. If the heart is being transplanted, the symptoms may include shortness of breath, chest pain, and fatigue.

Diagnosis of HLA incompatibility is typically done through a biopsy of the transplanted organ, which is then examined under a microscope for signs of rejection. Blood tests may also be done to determine the levels of antibodies in the recipient's blood, which can indicate whether or not the recipient is sensitized to the donor's HLA antigens.

Test Cost

The cost of the HLA Pre-Transplant Workup for Non-Sensitized Recipient Panel1 test in India is INR 22,230. This cost may vary depending on the location of the laboratory and any additional tests that may be required.

Conclusion

The HLA Pre-Transplant Workup for Non-Sensitized Recipient Panel1 test is an important diagnostic tool for patients who are in need of an organ transplant. This test can help determine the compatibility of a potential donor for a non-sensitized recipient, which can increase the chances of a successful transplant. If you are in need of an organ transplant, talk to your doctor about the HLA Pre-Transplant Workup for Non-Sensitized Recipient Panel1 test and whether or not it is right for you.

At DNA Labs India, we offer a wide range of diagnostic tests, including the HLA Pre-Transplant Workup for Non-Sensitized Recipient Panel1 test. Our team of experienced professionals is dedicated to providing accurate and timely results, so you can make informed decisions about your health. Contact us today to learn more about our services and how we can help you.

Pre-Kidney transplantation workup in Non sensitized recipient to: ƒ?› Assess the HLA match/mismatch between recipient & donor ƒ?› Antibody screening for allo-immunization status of the recipient Detect presence of complement fixing allo-antibodies in the recipient.

Step 1

Sample Collection

Collect specimen preferably 48 hours after dialysis. Ensure doctor's prescription on letterhead with one photograph each of recipient and donor duly stamped. Consent form for HLA Typing for Solid organ transplant (Form 33) is mandatory.

Method: Venipuncture

Step 2

Laboratory Analysis

Standard venipuncture procedure under sterile conditions.

Step 3

Report Delivery

Label samples accurately and ship refrigerated. Do not freeze.

Timeline: 10-12 days

Patient Instructions

1
Before the Test:Ensure all documentation (consent form, prescription) is ready. Follow collection timing guidelines.
2
During the Test:Blood samples will be collected via standard procedures.
3
After the Test:Samples sent for analysis; reports available in 10-12 days.

About This Test

Who Should Get This Test

Recipient: HLA DNA Typing for Kidney/Liver transplant (PCR Low resolution Luminex), HLA T & B cell lymphocyte cross match vs potential donor, HLA Panel Reactive IgG antibodies (PRA) Screen Luminex. This workup aims to assess HLA match/mismatch, detect allo-immunization status, and identify complement-fixing allo-antibodies to predict transplant compatibility.

Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_
ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_
ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_
Detect presence of complement fixing allo-antibodies in the recipient.

Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_
ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_
ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_
Detect presence of complement fixing allo-antibodies in the recipient.

How to Prepare

  • Collect whole blood in specified tubes (ACD, EDTA) and serum in SST
  • Ensure specimens are collected 48 hours post-dialysis if applicable
  • Include signed consent form (Form 33) and doctor's prescription with photos
  • Ship samples refrigerated; avoid freezing

Doctor's Notes

"This test is crucial for evaluating donor-recipient compatibility in non-sensitized patients awaiting organ transplantation, particularly for kidneys or livers, to minimize rejection risks."

Test Parameters & Specifications

Sample TypeWhole blood and serum
Sample Volume6 mL whole blood in ACD tube, 3 mL serum in SST, 4 mL whole blood in EDTA tube
ContainerYellow Top (ACD) tube, SST (Serum Separator Tube), Lavender Top (EDTA) tube
Collection MethodVenipuncture

Sample Stability

Room Temperature
Refrigerator (2-8°C)
Frozen
Sample Rejection Criteria:
  • Missing consent form or prescription
  • Sample hemolysis
  • Incorrect storage
  • Inadequate sample volume

Understanding Your Results

Results indicate HLA compatibility and antibody status. Compatibility is determined by HLA match/mismatch, cross-match negativity, and low PRA levels. Positive cross-match or high PRA may require further evaluation.
📊

HLA Match

Higher compatibility reduces rejection risk

📊

Negative Cross-Match

No donor-specific antibodies detected, favorable for transplant

📊

Low PRA (<20%)

Lower sensitization, better transplant outcomes

📊

Positive Cross-Match or High PRA

Indicates sensitization; may require desensitization or alternate donor

⚠️ When to Consult a Doctor:

Consult your nephrologist or transplant specialist if results show incompatibility, high antibody levels, or if you have questions about transplant readiness.

Limitations

  • ⚠Results are qualitative and require specialist interpretation
  • ⚠Cannot predict all forms of rejection
  • ⚠Limited to non-sensitized recipients

Risks & Considerations

  • ●Minor bruising at puncture site
  • ●Rare infection risk
  • ●Minimal discomfort

Interfering Factors

  • ●Recent blood transfusions
  • ●Dialysis within 48 hours
  • ●Sample hemolysis
  • ●Improper sample storage

Frequently Asked Questions

What is the HLA Pre-Transplant Workup for non-sensitized recipients?
It is a diagnostic test assessing donor-recipient compatibility for organ transplants in patients without prior HLA exposure.
Who needs this test?
Patients awaiting organ transplants, such as kidney or liver, who are non-sensitized recipients.
How is the test performed?
Using methods like Luminex technology for HLA typing, cross-matching, and antibody screening.
What samples are required?
Whole blood in ACD and EDTA tubes, and serum in an SST tube.
Is fasting required?
No, but specimens should be collected 48 hours after dialysis if applicable.
What is the cost of this test?
INR 22230 at DNA Labs India, with free home collection available.
How long does it take to get results?
10-12 days after sample collection.
What documents are needed for the test?
Doctor's prescription with photos and a signed consent form (Form 33).
What does a positive cross-match mean?
It indicates donor-specific antibodies, suggesting higher rejection risk and possibly requiring further evaluation.
Can this test be done at home?
Yes, DNA Labs India offers free home sample collection in many cities across India.
Is the test covered by insurance?
Coverage varies; check with your insurance provider or scheme like PMJAY or CGHS.
What if I have a high PRA level?
High PRA indicates sensitization; consult your transplant specialist for desensitization options or alternate donors.
Worried about the process? Our certified phlebotomists collect thousands of samples every month across India. The process takes under 5 minutes and is virtually painless. Questions? Message us on WhatsApp — we're here 7 days a week.
For Hospitals & Clinics

Reference Laboratory Services

We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.

LIMS Integration

Your Data Privacy

Your medical data is protected under Indian law.

✓ Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.

✓ DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.

Book Your Test

Enter your details and we'll connect you within 15 minutes.

🧬

Quick Connect

Enter your mobile number and we’ll connect you with the team.

+91

✅ Connecting you now...

🔒 Your number is used to respond to this request.