Skip to main content
DNA Labs India

HLA Pre-Transplant Workup Non Sensitized Recipient Panel 1 Test

DNA Labs India | ISO 9001:2015 Certified

HLA Pre-Transplant Workup Non Sensitized Recipient Panel 1 Test

Short Name: HLA Panel 1 Non-Sensitized Recipient

HLA Pre-Transplant Workup Non Sensitized Recipient Panel 1 Test test available at DNA Labs India for ₹16,380. Uses Complement Dependent Cytotoxicity with DTT treatment, Reverse SSOP - Luminex, Luminex X-Map technology on Whole Blood samples. Results in 10-12 days. Free home collection in 300+ cities across India.

Laboratory TestAll Ages🏠 Home Collection

🩺 Medically Reviewed By

Overview

To assess HLA compatibility between donor and recipient for kidney, liver, or other solid organ transplants in non-sensitized recipients, ensuring optimal donor selection and reducing transplant risks. Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_ ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_ ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_ Detect presence of complement fixing allo-antibodies in the recipient. Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_ ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_ ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_ Detect presence of complement fixing allo-antibodies in the recipient.

Test Code
815
Price
₹16,380
Sample Type
Whole Blood
Result Time
10-12 days
Fasting Required
No
Method
Complement Dependent Cytotoxicity with DTT treatment, Reverse SSOP - Luminex, Luminex X-Map technology

For patients in need of a bone marrow or solid organ transplant, the HLA pre-transplant workup is a critical step to ensure compatibility between donor and recipient. In the case of non-sensitized recipients, the HLA panel1 test is an important component of the pre-transplant workup.

Symptoms

Symptoms that may indicate the need for a transplant include severe organ failure, decreased organ function, and a life-threatening illness. Patients with end-stage renal disease, liver failure, heart failure, or lung disease may require a transplant to improve their quality of life and increase their life expectancy.

Diagnosis

Diagnosis of the need for a transplant is typically made by a physician after a thorough evaluation of the patient's medical history, current health status, and diagnostic test results. In some cases, a biopsy may be necessary to confirm the diagnosis.

HLA Pre-Transplant Workup

The HLA pre-transplant workup is a series of tests that are performed to determine the compatibility between donor and recipient. HLA stands for human leukocyte antigen, which is a protein that is found on the surface of cells and is used by the immune system to recognize self from non-self.

The HLA panel1 test is used for non-sensitized recipients, which means that the patient has not previously been exposed to foreign antigens that could cause an immune response. The test is used to determine the patient's HLA type and identify potential donors who have a compatible HLA type.

Test Cost

The cost of the HLA panel1 test for non-sensitized recipients is INR 16,380. This test is typically covered by insurance for patients who meet certain criteria.

Conclusion

The HLA pre-transplant workup is a critical step in the transplant process to ensure compatibility between donor and recipient. For non-sensitized recipients, the HLA panel1 test is an important component of the workup. Patients who are in need of a transplant should speak with their physician to determine if they are a candidate for the HLA pre-transplant workup.

At DNA Labs India, we provide HLA panel1 testing and other diagnostic services to support the transplant process. Contact us today to learn more about our services.

Pre-Kidney transplantation workup in Non sensitized recipient to: ƒ?› Assess the HLA match/mismatch between recipient & donor ƒ?› Antibody screening for allo-immunization status of the recipient Detect presence of complement fixing allo-antibodies in the recipient.

Step 1

Sample Collection

Doctor's prescription on letterhead with 1 photograph each of recipient and donor duly stamped, and Consent form for HLA Typing for Solid organ transplant (Form 33) is mandatory.

Method: Venipuncture

Step 2

Laboratory Analysis

Blood samples collected via venipuncture from the donor.

Step 3

Report Delivery

Samples must be shipped refrigerated and not frozen.

Timeline: 10-12 days

Patient Instructions

1
Before the Test:Ensure all required documents (prescription and consent form) are prepared, and follow any specific instructions from the healthcare provider.
2
During the Test:Blood draw from the donor using standard venipuncture techniques.
3
After the Test:Results will be available in 10-12 days; consult with your transplant team for interpretation.

About This Test

Who Should Get This Test

To assess HLA compatibility between donor and recipient for kidney, liver, or other solid organ transplants in non-sensitized recipients, ensuring optimal donor selection and reducing transplant risks.

Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_
ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_
ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_
Detect presence of complement fixing allo-antibodies in the recipient.

Pre-Kidney transplantation workup in Non sensitized recipient to:_x000D_
ƒ?› Assess the HLA match/mismatch between recipient & donor_x000D_
ƒ?› Antibody screening for allo-immunization status of the recipient_x000D_
Detect presence of complement fixing allo-antibodies in the recipient.

How to Prepare

  • Obtain doctor's prescription on letterhead with stamped photographs of recipient and donor
  • Complete and submit Consent form for HLA Typing for Solid organ transplant (Form 33)
  • Collect 12 mL whole blood in 2 Yellow Top (ACD) tubes and 4 mL whole blood in 1 Lavender top (EDTA) tube from donor
  • Ship samples refrigerated; do not freeze

Doctor's Notes

Reviewed by — MBBS, MD (Pathology) · Reg. No. 21521

Last updated: November 19, 2026

Test Parameters & Specifications

Sample TypeWhole Blood
Sample Volume12 mL (10 mL min.) in 2 Yellow Top (ACD) tubes AND 4 mL (2 mL min.) in 1 Lavender top (EDTA) tube
ContainerYellow Top (ACD) tubes, Lavender top (EDTA) tube
Collection MethodVenipuncture

Sample Stability

Refrigerator48 hours
Room TemperatureNot applicable
FrozenNot applicable

Understanding Your Results

HLA typing results determine the degree of match between donor and recipient, influencing transplant compatibility and risk of rejection.
📊

High HLA Match

📊

Low HLA Match

📊

Presence of Allo-antibodies

⚠️ When to Consult a Doctor:

When considering organ transplantation, if symptoms of organ failure are present, or after receiving test results to discuss donor selection and transplant planning.

Frequently Asked Questions

What is the HLA Pre-Transplant Workup Panel 1 Test?
This test is a series of assessments, including HLA typing, to determine compatibility between donor and recipient for bone marrow or solid organ transplants in non-sensitized recipients.
Why is HLA typing important for transplantation?
HLA typing helps identify the best donor match, reducing the risk of transplant rejection and improving long-term outcomes.
What does 'non-sensitized recipient' mean?
It refers to a patient who has not been previously exposed to foreign antigens that could cause an immune response, simplifying the transplant workup.
What is the cost of this test at DNA Labs India?
The test costs INR 16380, which includes free home sample collection across India.
What samples are required for the test?
Donor samples: 12 mL whole blood in 2 Yellow Top (ACD) tubes and 4 mL whole blood in 1 Lavender top (EDTA) tube. Recipient samples may also be required per prescription.
How long does it take to get results?
Results are typically available in 10-12 days.
What documents are needed before the test?
A doctor's prescription on letterhead with stamped photographs of recipient and donor, and a Consent form for HLA Typing for Solid organ transplant (Form 33) are mandatory.
Is fasting required for this test?
No, fasting is not required for this blood test.
Can this test be done at home?
Yes, DNA Labs India offers free home sample collection for this test across India.
What conditions indicate the need for this test?
Conditions include end-stage renal disease, liver failure, heart failure, lung disease, or other life-threatening illnesses requiring organ transplantation.
What methods are used for HLA typing in this test?
Methods include Complement Dependent Cytotoxicity with DTT treatment, Reverse SSOP - Luminex, and Luminex X-Map technology.
Is the test covered by insurance?
It is typically covered by insurance for patients meeting certain criteria, but coverage may vary by insurer and policy.
Worried about the process? Our certified phlebotomists collect thousands of samples every month across India. The process takes under 5 minutes and is virtually painless. Questions? Message us on WhatsApp — we're here 7 days a week.

Related Tests

For Hospitals & Clinics

Reference Laboratory Services

We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.

LIMS Integration

Your Data Privacy

Your medical data is protected under Indian law.

✓ Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.

✓ DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.

Book Your Test

Enter your details and we'll connect you within 15 minutes.

🧬

Quick Connect

Enter your mobile number and we’ll connect you with the team.

+91

✅ Connecting you now...

🔒 Your number is used to respond to this request.